configure cfm segment frame-loss window

configure cfm segment segment_name frame-loss window window_size

Description

This command is used to configure the window size for calculating the alarm/clear threshold values for DMM and Severely Errored Second (SES) threshold for LMM. This window size denotes the total number of recent frames for which the threshold values will be measured.

If the optional keyword frame-delay or frame-loss is not specified, the same value of window size will be used for both DMM and LMM. The optional keyword allows configuring values for DMM and LMM.

Syntax Description

segment_name

Alphanumeric string identifying the segment name.

frame-loss

Y.1731 Ethernet frame loss measurement.

window_size

Window size for loss measurement; number of frames 1-1800 to be used.

Default

1200.

Usage Guidelines

Use this command to configure the window size for calculating the alarm/clear threshold values for DMM and Severely Errored Second (SES) threshold for LMM.

Example

configure cfm segment cs2  frame-loss  window 900

History

This command was first available in ExtremeXOS 15.1.

Platform Availability

This command is available on all Universal switches supported in this document.